T-Zaehler

Water Meter

Hot and cold water · TX-15 / 20 / 25

The TX series mechanical water meter combines the measuring element and the register in one compact body. The brass lower body is built to last, and the eight-digit register makes consumption readable at a glance. Every size comes in a hot water and a cold water version, without a module or with an M-Bus or RF module.

  • DN15 – DN25
  • Hot and cold water
  • No module, M-Bus or RF
  • MID certified
  • R80
  • IP65

Request a quote Models

T-Zaehler brass water meter with OMS-compatible 868 MHz RF (wireless M-Bus) module

18 configurations

Models

Three sizes, hot and cold water versions, three module options: eighteen configurations. Hot and cold water versions share the same product code.

Size
Use
Module

Selected model

TX-15

DN15 · Hot water · M-Bus

Size
DN15G 3/4" connection, Q3 2.5 m³/h.
Use
Hot waterFor domestic hot water installations.
Module
M-BusCentral reading over a wired M-Bus line.
Request a quote for this model

Ask us about Modbus, LoRa and pulse output modules.

Features

A long-lasting body, a clear register and modules that fit the building's reading network.

  • Compact design: measuring element and register in one unit.
  • Brass lower body for strength and long life.
  • Suitable for cold water and domestic hot water.
  • 8-digit roller register for clear reading.
  • MID certified, R80 measuring range.
  • IP65 protection, accuracy class 2.
  • Without a module, or with an M-Bus or RF (OMS, wM-Bus 868 MHz) module; Modbus, LoRa and pulse modules on request.
  • Low pressure loss.
  • Magnetic protection; manufactured to TS EN 14154.
  • Meets OIML R49-1, R49-2 and R49-3.
  • 12 months of historical data; no data produced on reverse flow.
  • 2-year warranty and long-term spare parts support.
  • Environment: climatic −10 °C / +55 °C, mechanical M1, electromagnetic E2.

Technical data

Values may vary by model and configuration.

ParameterUnitTX-15TX-20TX-25
Nominal size (DN)mm152025
Q3 / Q1–80
Minimum flow (Q1)l/h31.2031.2078.7
Transitional flow (Q2)l/h5050126
Permanent flow (Q3)m³/h2.52.56.3
Overload flow (Q4)m³/h3.1253.1257.8
Q2 / Q1–1.6
Connection thread–G 3/4"G 1"G 1 1/4"
Installation–Horizontal
Max. working temperature (T)°C50 (cold water) · 90 (hot water version)
Max. working pressurebar16
Pressure lossbar0.63
Max. permissible error, upper zone%Q2 ≤ Q ≤ Q4: ±2 (Θ ≤ 30 °C), ±3 (Θ > 30 °C)
Max. permissible error, lower zone%Q1 ≤ Q < Q2: ±5 (class 2), ±3 (class 1)
Verification scale intervalm³0.00005
Body–Brass
Mechanical / electromagnetic class–M1 / E2
Maximum registerm³99 999

Installation and maintenance

Ignoring these rules can affect measuring accuracy and the reliability of remote reading.

  • Flush the pipework before installation.
  • Install in the direction of flow, horizontally only.
  • Clean strainers and sediment traps regularly after installation.
  • Keep meter niches away from high-voltage lines and leave enough room for service access.
German engineering

Design and measurement architecture follow European standards.

Made in Türkiye

Manufactured in our own facilities, with fast delivery and service.

Energy savings

When everyone pays for what they use, the whole building uses less.

Reliable performance

Every device is tested before shipping, with spare parts for many years.

Let's choose the right devices for your building

Site surveys are free. Just tell us the number of flats and the type of installation.

Request a free survey